IKUSI receiver - R70
R70
Compact and flexible receiver with extensive
capabilities for advanced industrial or mobile
applications with following essential features:
- up to 29 relay outputs and other expansion
possibilities: analogue outputs, industrial
communication interfaces, additional analogue and
digital inputs, and many more…
- customizable configuration
- external and removable configuration
module (EEPROM)
- selectable power supply 48/115/230Vac
- STOP circuit: Category 3 – PLd according to
EN ISO 13849-1
- dual band radio module (suitable for full
duplex feedback)
Can be associated with following transmitters: T70/1, T70/2, T70/1-ATEX,T70/2-ATEX, IK2, IK3, IK4
SPECIFICATIONS
Feature |
Description |
Stop Function |
Cat.3 - PLd |
Ingress protection |
IP65/NEMA4 |
Frequency Band |
dual band, 400-930 MHz |
AC Power Supply |
multi voltage, 48/115/230 Vac |
DC Power Supply |
9-30Vdc |
Antenna |
internal (optional external) |
Removable EEPROM |
internal |
Status indication |
internal LEDs |
Digital relay outputs |
max. 29 |
Analogue output |
max. 8 |
Industrial bus communication |
optional (CANOpen, Profibus-DP or SAE J1939) |
Digital inputs |
max. 44 |
Analogue Inputs |
max. 8 |
Maximum output Current |
8A |
Working Temperature Range |
-4°F +158°F (-20°C +70°C) |
Weight |
configuration dependent |
Dimensions |
285x200x110mm (LxWxH) |
Cable output |
cable gland M32 |
Associated Transmitters |
T70/1, T70/2, T70/1-ATEX, T70/2-ATEX, IK2, IK3, IK4 |
R70 ATEX
The R70 ATEX or RATEX is an compact and flexible receiver with extensive capabilities for advanced industrial or mobile applications in hazardous areas with following essential features:
- up to 29 relay outputs and other expansion possibilities: analogue outputs, industrial communication interfaces, additional analogue and digital inputs, and many more…
- customizable configuration
- external and removable configuration module (EEPROM)
- selectable power supply 48/115/230Vac
- STOP circuit: Category 3 – PLd according to EN ISO 13849-1
- dual band radio module (suitable for full duplex feedback)
Can be associated with following transmitters: T70/1-ATEX, T70/2-ATEX
SPECIFICATIONS
Feature |
Description |
Stop Function |
Cat.3 - PLd |
Ingress protection |
IP65/NEMA4 |
Frequency Band |
dual band, 400-930 MHz |
AC Power Supply |
multi voltage, 48/115/230 Vac |
DC Power Supply |
n.a. |
Antenna |
external |
Removable EEPROM |
internal |
Status indication |
internal LEDs |
Digital relay outputs |
max. 29 |
Analogue output |
max. 8 |
Industrial bus communication |
optional (CANOpen, Profibus-DP or SAE J1939) |
Digital inputs |
max. 44 |
Analogue Inputs |
max. 8 |
Maximum output Current |
8A |
Working Temperature Range |
-4°F +158°F (-20°C +70°C) |
Weight |
configuration dependent |
Dimensions |
285x200x110mm (LxWxH) |
Cable output |
n.a. |
Associated Transmitters |
T70/1-ATEX, T70/2-ATEX |
CERTIFICATIONS
> ATEX |
II 2 GD |
Ex d ia IIB T5 |
Ex tD iaD A21 IP65 T100°C |
T.amb :-20°C +70°C |
CE0080 |
INERIS 08ATEX029 |
R70 plus
Large receiver with extensive capabilities for advanced industrial applications with following essential features:
- up to 53 relay outputs and other expansion possibilities: analogue outputs, industrial communication interfaces, additional analogue and digital inputs, and many more…
- customizable configuration
- external and removable configuration module (EEPROM)
- selectable power supply 48/115/230Vac
- STOP circuit: Category 3 – PLd according to EN ISO 13849-1
- dual band radio module (suitable for full duplex feedback)
Can be associated with following transmitter IK2, IK3, IK4
SPECIFICATIONS
Feature |
Description |
Stop Function |
Cat.3 - PLd |
Ingress protection |
IP65/NEMA4 |
Frequency Band |
dual band, 400-930 MHz |
AC Power Supply |
multi voltage, 48/115/230 Vac |
DC Power Supply |
9-30Vdc |
Antenna |
external |
Removable EEPROM |
internal |
Status indication |
internal LEDs |
Digital relay outputs |
max. 53 |
Analogue output |
max. 10 |
Industrial bus communication |
CANOpen, Profibus-DP or SAE J1939 |
Digital inputs |
max. 4 |
Analogue Inputs |
max. 8 |
Maximum output Current |
8A |
Working Temperature Range |
-4°F +158°F (-20°C +70°C) |
Weight |
configuration dependent |
Dimensions |
350x250x150mm (LxWxH) |
Cable output |
cable gland M32 |
Associated Transmitters |
IK2, IK3, IK4 |